New XMPro Agent Integration: OPC UA Action Agent

Here at XMPro, we are constantly adding to our growing library of integrations for enterprise applications, data platforms, machine learning tools, and operational systems. These pre-built integrations allow our customers to build composable digital twins that are not only scalable but highly customizable for their specific use cases.

We are excited to announce that OPC UA is the latest agent to join our catalog. OPC UA integration now also features an Action Agent

OPC UA is a platform-independent standard through which various systems and devices communicate by sending request and response Messages between Clients and Servers or network messages between Publishers and Subscribers over supported network types such as HTTPS and HTTP.

In the OPC UA Client-Server model, a set of Services acts as the interface between Clients and Servers. Object information from the Server that is made available to the Client is called the Address Space and is exposed in formats such as XML and JSON.

The basic component of the Address Space is a Node, which contains values or references to other nodes. The referenced nodes represent the hierarchy structure.

The OPC UA Agents allow you to traverse the Server Address Space represented by Branches and to include nodes as tags in your Data Stream, using the OPC UA Client-Server model to connect to an OPC UA Server endpoint.

For more information regarding the OPC UA standards, please see the Unified Architecture specification.

The Listener allows you to retrieve tag values of the selected nodes on the OPC UA Server.

The Action Agent allows you to publish the supplied tag values and its timestamp to the selected nodes on the OPC UA Server.

EXAMPLE

Step 1: Add the Agent
Drag the OPC UA Action Agent onto the canvas and rename it. Link the input endpoint to the Boiler 1 Data, then the output endpoint to the printer, and save the Data Stream.
Step 2: Configure General
Select the Agent and click Configure. In this case, keep the default Collection and polling interval.
Step 3: Configure Connection
Enter the Connection details of your OPC UA Server: server url, endpoint, and security. In this case, tick to use variables, select the server url, “opc.tcp – None – None – Binary” as the endpoint, and Anonymous as the security.
Step 3: Configure Connection
Enter the Connection details of your OPC UA Server: server url, endpoint, and security. In this case, tick to use variables, select the server url, “opc.tcp – None – None – Binary” as the endpoint, and Anonymous as the security.
Step 4: Configure Specify Branch
Select the Branch Navigation and Path. In this case, leave it as Using Dot Notation, and enter the Branch Path as Objects.Boilers.Boiler #1.LC1001.
Step 5: Configure Tags
Select from the Available Tags and click Add Selected Tags to populate the Tags Grid. In this case, select SetPoint.
Then assign the corresponding Tag Value for the tag in the Tags Grid. In this case, also select SetPoint from the input payload.
Step 6: View Results
Apply the changes, save the Data Stream and publish it.